Brand > Type > Error code > E.02.32
Error code:
E.02.32
Cause
Lockout because the automatic (re)filling of the installation takes too long.
Refilling the central heating system takes too long:
- Check the installation for leaks.
- Check the system water pressure.
- Check whether the tap of the inlet combination is properly opened.
- Check whether the main water tap is properly opened.
- Check the operation of the pressure sensor.
- Check the operation of the safety valve.
This malfunction requires the help of a professional